6. SysEx Messages
38
14 : Disable Encoder Local Control
This message can enable or disable Ring Local Control for the encoders.
Total Bytes: 8
Data Bytes: 1
1st Data Byte Received: Local Control Disabled?
0 = Enabled
1+ = Disabled
Message for Default Settings (Enabled):
< 240, 0, 1, 106, 01, 14, 0, 247 >
15 : Disable Potentiometer Center Note Messages
This message can enable or disable the Note On and O messages that are sent by the potentiometer
when the control enters and leaves the center detent.
Total Bytes: 8
Data Bytes: 1
1st Data Byte
Received:
Local Control Disabled?
0 = Enabled
1+ = Disabled
Message for Default Settings (Enabled):
< 240, 0, 1, 106, 01, 15, 0, 247 >
126 : Request Controller Conguration
This Message asks the TWEAKER to send a return message detailing all of its settings.
Total Bytes: 8
Data Bytes: 0
Message to Request Settings:
< 240, 0, 1, 106, 01, 126, 247 >